Milwaukee PH51 pH meter
Milwaukee PH51 pH meter

Milwaukee PH51 pH meter

In Stock

38.89EUR

 The price of the product may differ from the price of the product available in our stores
Product code: GRO3151 Warranty: According to law, price band* The stock shown in the webshop does not match the
stock in our stores.

Inquire about the stock of our stores by phone, the contact
details of our stores can be found here.

Description

The Milwaukee PH51 pH meter is a waterproof pH tester. Performs automatic temperature compensation (ATC) for each pH measurement.

The meter can be calibrated at two points. Accurate measurements are displayed directly on the LCD display. The MA73600 electrode supplied with the meter is simple and easy to replace. The closed temperature sensor allows fast and accurate temperature measurement and compensation.

Technical details:

pH measuring range 0.0 to 14.0 pH
pH resolution 0.1 pH
pH accuracy (@ 25 ° C / 77 ° F) ±0.1 pH
pH calibration automatic, 2 points; pH 4.0 and pH 7.0 or pH 7.0 and pH 10.0
pH probe MA73600
Temperature compensation automatic
Battery 3 x 1.5V button cells
Battery life approx. 250 hours of use
Operating environment 0-50 ° C (32-122 ° F); RH 100%
Dimensions 165 x 30 x 30 mm
Weight 80 g


Electrode maintenance:

  • when not in use, rinse the electrode with water and place a few drops of Milwaukee storage solution in the protective cap and store it in it
  • never store the electrode in distilled or deionized water
  • if the electrode is left dry, soak the end in storage solution for at least one hour to reactivate
  • to prolong electrode life, it is recommended to clean monthly by immersing the tip in Milwaukee general cleaning solution for 30 minutes, then rinse thoroughly with tap water and recalibrate the meter

The electrode is easy to replace.


Use:
Two vessels are used for calibration. Both must be filled with the same calibration solution, but the first vessel is for rinsing the probe only, the actual calibration must be performed in the second vessel with the probe already rinsed. Always use fresh solution for calibration. This can be ensured with bag solutions for single calibration. If the instrument we use allows the use of several calibration solutions, it is advisable to use solutions close to the concentration of the measured sample. The EC meter does not need to be calibrated as often as the pH electrode, but regular monitoring is important as changes in the condition and aging of the probe can be compensated by calibration. It is advisable to read the instructions for use of the instrument, as there are measuring instruments that can only be calibrated with solutions of a certain value.

Instructions for use are available here.

Reviews

There are currently no product reviews.

The information herein is provided by the manufacturer.
Manufacturers can change product information at any time, without prior notice.
We are not liable for any changes.
All pictures shown are for illustration purpose only. The product may be different in reality.
Our sets may vary due to current stock availabilities. If any changes occur, customers will be informed in time.